Please use this identifier to cite or link to this item:
https://dspace.uzhnu.edu.ua/jspui/handle/lib/12799
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Потапчук, Анатолій Мефодійович | - |
dc.contributor.author | Мищенко, О.Н. | - |
dc.contributor.author | Мосейко, А.А. | - |
dc.contributor.author | Криванич, Володимир Миколайович | - |
dc.date.accessioned | 2017-04-03T09:48:39Z | - |
dc.date.available | 2017-04-03T09:48:39Z | - |
dc.date.issued | 2015 | - |
dc.identifier.citation | Концепция формы дентальных имплантатов системы Zircon Prior / А.М. Потапчук, О.Н. Мищенко, А.А. Мосейко, В.Н. Криванич // Хирургия. Восточная Европа. – 2015. – №2 (14). – С . 30-37. | uk |
dc.identifier.uri | https://dspace.uzhnu.edu.ua/jspui/handle/lib/12799 | - |
dc.description.abstract | В работе проведен анализ основных существующих форм зубных имплантатов. Описана разработка внутрикостной части имплантата, адаптированной к различным типам и участкам кости, а также адаптирующей различные участки кости к будущей нагрузке. Результаты биомеханических исследований распределения нагрузок на периимплантатную зону в зависимости от формы имплантата показали, что наиболее оптимальной является форма в виде параболоида, позволяющая равномерно распределять разновекторную нагрузку. Предложенная форма имплантата с комбинированной однозаходной макрорезьбой и двузаходной микрорезьбой позволяет адаптивно формировать имплантационное ложе в различных типах кости. Специфическая форма внутрикостной части имплантатов обеспечивает большую, в сравнении с другими формами, площадь контакта имплантат-кость. Доказав, что напряжения в кости достаточно хорошо коррелируют с общей площадью контактных по¬верхностей имплантатов, для снижения контактных напряжений было рекомендовано ис¬пользование мелкой резьбы в кортикальной части кости, а также атравматическая полусферическая формы верхушки. Ключевые слова: форма внутрикостной части имплантата, состояние кости переимплантатной зоны. | uk |
dc.description.abstract | The article devoted to the analyses of the main existing forms of dental implants. The development of the intraosseous implant part adapted to the various types and areas of the bone is described Such part provides also adaptation of different bone portions to the future bone exertion. The results of the biomechanical studies of exertion distribution within the peri-implant zone depending on the shape of the implant revealed that the most optimal form Is in the form of a paraboloid, which allows to evenly distribute the different vectored forces. The proposed shape of the implant with a combined single¬pass macro-screwy and dual-pass micro-screw allows adaptively generate Implantation zone in differ¬ent types of bone. The specific form of the intraosseous implant provides greater area of implant-bone contact comparing to other forms of implants. Based on the fact that the stresses in the bone correlate the total area of the contact surfaces of implants, the use of *ine screw in the cortical bone increased I of the top of the implants were recommended with a purpose to reduce contact stresses. Keywords: form of intraosseous implant part, bone condition at peri-implant zone. | uk |
dc.language.iso | ru | uk |
dc.relation.ispartofseries | Хирургия. Восточная Европа; | - |
dc.subject | форма внутрикостной части имплантата | uk |
dc.subject | состояние кости переимплантатной зоны | uk |
dc.title | Концепция формы дентальных имплантатов системы Zircon Prior | uk |
dc.title.alternative | Form concept of dental implant system Zircon Prior | uk |
dc.type | Text | uk |
dc.pubType | Стаття | uk |
Appears in Collections: | Наукові публікації кафедри стоматології післядипломної освіти |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Концепция формы дентальных имплантантов.pdf | 3.24 MB | Adobe PDF | View/Open |