Please use this identifier to cite or link to this item: https://dspace.uzhnu.edu.ua/jspui/handle/lib/60117
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBan, Henrietta-
dc.contributor.authorGal, David-
dc.contributor.authorGerasimov, Vitaly-
dc.contributor.authorHaysak, Andriy-
dc.contributor.authorMolnar, Alexander-
dc.date.accessioned2024-03-18T10:44:07Z-
dc.date.available2024-03-18T10:44:07Z-
dc.date.issued2021-09-22-
dc.identifier.citationAutomated measuring system for studying the temperature dependence of dielectric spectra of ferroelectrics / Henrietta Bán, David Gal, Vitaly Gerasimov, Andriy Haysak, Alexander Molnar // IDAACS 2021 The 11th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications. - September 22-25, 2021. - Cracow, Poland. - p.156-159.uk
dc.identifier.otherhttps://doi.org/10.1109/IDAACS53288.2021.9661058-
dc.identifier.urihttps://dspace.uzhnu.edu.ua/jspui/handle/lib/60117-
dc.descriptionAn automated measuring system developed by authors for studying the temperature dependence of dielectric spectra of ferroelectrics in the frequency range 12Hz-100kHz, the temperature range 80-450K and the amplitude of the measuring signal 5mV-1.275V has been presented. It is based on the GW Instek LCR-819 LCR Meter, the Measurement Computing USB-TEMP-AI temperature meter and an OWON ODP3033 programmable power supply. The temperature measurement resolution is 0.001K and the controlled rate of temperature change is from 0.001K/min to 1K/min. The control software, created in the LabVIEW graphical environment, makes it possible to carry out measurements in an automatic mode, present the results obtained in the form of graphs (Cole-Cole plot and frequency dependency of ε’ and ε”) and save the data as a file for further processing.uk
dc.description.abstractAn automated measuring system developed by authors for studying the temperature dependence of dielectric spectra of ferroelectrics in the frequency range 12Hz-100kHz, the temperature range 80-450K and the amplitude of the measuring signal 5mV-1.275V has been presented. It is based on the GW Instek LCR-819 LCR Meter, the Measurement Computing USB-TEMP-AI temperature meter and an OWON ODP3033 programmable power supply. The temperature measurement resolution is 0.001K and the controlled rate of temperature change is from 0.001K/min to 1K/min. The control software, created in the LabVIEW graphical environment, makes it possible to carry out measurements in an automatic mode, present the results obtained in the form of graphs (Cole-Cole plot and frequency dependency of ε’ and ε”) and save the data as a file for further processing.uk
dc.language.isoenuk
dc.publisherIEEE, Faculty of Electrical and Computer Engineering, Cracow University of Technology, Cracow, Polanduk
dc.subjectdielectric spectrauk
dc.subjecttemperature dependenceuk
dc.subjectferroelectricsuk
dc.titleAutomated measuring system for studying the temperature dependence of dielectric spectra of ferroelectricsuk
dc.typeTextuk
dc.pubTypeСтаттяuk
Appears in Collections:Наукові публікації кафедри фізики напівпровідників

Files in This Item:
File Description SizeFormat 
2021_IDAACS_VOL_1_156 (3).pdfarticle1.73 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.