Please use this identifier to cite or link to this item: https://dspace.uzhnu.edu.ua/jspui/handle/lib/36141
Title: ПОКАЗАТЕЛИ СИЛЫ АДГЕЗИИ К ТВЕРДЫМ ТКАНЯМ НЕВИТАЛЬНЫХ ЗУБОВ СТОМАТОЛОГИЧЕСКИХ ФОТОКОМПОЗИТНЫХ ПЛОМБИРОВОЧНЫХ МАТЕРИАЛОВ В КОМБИНАЦИИ С РАЗЛИЧНЫМИ АДГЕЗИВНЫМИ СИСТЕМАМИ
Other Titles: THE STRENGTH OF ADHESION TO HARD TISSUES OF NON-VITAL TEETH OF DENTAL PHOTOCOMPOSITE FILLING (RESTORATIVE) MATERIALS IN COMBINATION WITH VARIOUS ADHESIVE SYSTEMS
სირთულეების კბილების ფოტოკომპპოზიტური შემავსებელი მასალების ძნელოვანი კბილების მყარი ქსოვილების ადჰეზიის ძნელად აღმნიშვნელი ინდიკატორები
Authors: Мочалов, Юрій Олександрович
Кеян, Давид Миколайович
Пасічник, Мар'яна Андріївна
Кравцов, Руслан Васильович
Keywords: адгезия, фотокомпозит, пломба, сила, зуб
Issue Date: Jun-2021
Publisher: Ассоциация деловой прессы Грузии
Citation: Мочалов Ю.А., Кеян Д.Н., Пасичнык М.А., Кравцов Р.В. Показатели силы адгезии к твердым тканям невитальных зубов стоматологических фотокомпозитных пломбировочных материалов в комбинациис различными адгезивными системами. Медицинские новости Грузии. 2021; 6 (315): 61-65.
Abstract: Резюме Усовершенствование механизмов и показателей силы адгезии стоматологических фотокомпозиционных пломбировочных материалов к твердым тканям зубов, усовершенствование пломбировочных материалов и повышение их доступности является актуальной проблемой для теоретической и практической стоматологии. Цель исследования: экспериментальная оценка силы адгезии к твердым тканям невитальных зубов отдельных адгезивных систем в комбинации с современными фотокомпозитными пломбировочными материалами. Материалы и методы: проведено 80 тестов силы адгезии стоматологического фотокопозитного пломбировочного материала к твердым тканям зуба (прочность на сдвиг) для 8 пар “фотокомпозит-адгезивная система” при помощи автоматизированной тензометрической системы. Результаты: сила адгезии пломбировочного материала к твердым тканям невитальных зубов (прочность на сдвиг) имеет широкий диапазон отличий. Средняя величина составила 18,74±4,48 (М=19,63) МПа, среднее минимальное значение равнялось 10,89±2,47 (М=9,95) МПа, а максимальное – 33,18±16,35 (М=24,35) МПа, при этом отдельные пары материалов и адгезивных систем демонстрировали силу адгезии от 8,56 до 66,00 МПа. Ключевые слова: адгезия, фотокомпозит, пломба, сила, зубы.
Summary Improvement the mechanisms and levels of adhesion forces of dental photocomposite filling (restorative) materials to hard tissues of teeth, improvement of filling materials and increasing their availability is an urgent problem for theoretical and practical dentistry. Aim of the study: experimental evaluation of the strength of adhesion to the hard tissues of non-vital teeth for adhesive systems in combination with modern dental photocomposite filling (restorative) materials. Materials and methods: 80 tests of the adhesion strength of the dental photocomposite filling (restorative) material to the tooth hard tissues (shear strength) were carried out for 8 pairs of “photocomposite-adhesive system” using an automated tensometric system. Results: the strength of adhesion of the filling material to the hard tissues of non-vital teeth (shear strength) has a wide range of differences. The average value was 18.74 ± 4.48 (M = 19.63) MPa, the average minimum value was 10.89 ± 2.47 (M = 9.95) MPa, and the maximum value was 33.18 ± 16.35 ( M = 24.35) MPa, while individual pairs of materials and adhesive systems demonstrated an adhesion force from 8.56 to 66.00 MPa. Key words: adhesion, photocomposite, filling, strength, teeth.
რეზიუმე კბილების მყარ ქსოვილებზე სტომატოლოგიური ფოტოკომპოზიტის შემავსებელი მასალების გადაბმის მექანიზმისა და ინდიკატორების გაუმჯობესება, შემავსებელი მასალების გაუმჯობესება და მათი ხელმისაწვდომობის გაზრდა წარმოადგენს გადაუდებელ პრობლემას თეორიული და პრაქტიკული სტომატოლოგიისათვის. კვლევის მიზანი: ინდივიდუალური წებოვანი სისტემის მყარი ქსოვილების მყარ ქსოვილებზე გადაბმის სიძლიერის ექსპერიმენტული შეფასება თანამედროვე ფოტოკომპოზიტის შემავსებელ მასალებთან ერთად. მასალები და მეთოდები: ჩატარდა სტომატოლოგიური ფოტოკომპოზიტის შემავსებელი მასალის გადაბმის სიძლიერის 80 ტესტი მყარ კბილთა ქსოვილებზე (წანაცვლების სიმტკიცე) ავტომატიზირებული ტენსომეტრიული სისტემის გამოყენებით 8 წყვილი ”ფოტოკომპოზიტ-წებოვანი სისტემისთვის”. შედეგები: არა სასიცოცხლო მნიშვნელობის კბილების მყარ ქსოვილებზე შემავსებელი მასალის გადაბმის სიძლიერეს (წანაცვლების სიძლიერე) აქვს მრავალფეროვანი განსხვავება. საშუალო მნიშვნელობა იყო 18.74 ± 4.48 (M = 19.63) MPa, საშუალო მინიმალური მნიშვნელობა იყო 10.89 ± 2.47 (M = 9.95) MPa, ხოლო მაქსიმალური ღირებულება 33.18 ± 16.35 ( M = 24,35) MPa, ხოლო ცალკეულმა მასალებმა და წებოვანმა სისტემებმა აჩვენეს გადაბმის ძალა 8,56 – დან 66,00 MPa– მდე. საკვანძო სიტყვები: ადჰეზია, ფოტოკომპოზიტი, შევსება, ძალა, კბილები.
Type: Text
Publication type: Стаття
URI: https://dspace.uzhnu.edu.ua/jspui/handle/lib/36141
ISSN: 1512-0112
Appears in Collections:Наукові публікації кафедри хірургічної стоматології та клінічних дисціплин

Files in This Item:
File Description SizeFormat 
61-65.pdftext1.01 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.