Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: https://dspace.uzhnu.edu.ua/jspui/handle/lib/47238
Название: Intraoral scanning, CBCT, and surface electromyography combination: efficiency analysis of proposed diagnostic “Trident” algorithm during complex dental rehabilitation. 
Авторы: Tukalo, I.
Rusyn, V.
Hirschowitz, W.
Goncharuk-Khomyn, M.
Ключевые слова: CBCT; electromyography; intraoral scanning; Oral Satisfaction Scale
Дата публикации: 2022
Издательство: Journal of Dentistry
Библиографическое описание: Tukalo, I., Rusyn, V., Hirschowitz, W., & Goncharuk-Khomyn, M. (2022). Intraoral scanning, CBCT, and surface electromyography combination: Efficiency analysis of proposed diagnostic “Trident” algorithm during complex dental rehabilitation. Journal of Dentistry, 121, 104015.
Серия/номер: 121;
Краткий осмотр (реферат): Purpose.To evaluate the efficiency of dental treatment supported by the complex diagnostic algorithm consisting of digital scanning, CBCT, and surface electromyography procedures (“TRIDENT” algorithm) considering clinically objective and patient-oriented subjective criteria. Methods. The study cohort was formed out of 47 patients, who underwent implant placement and rehabilitation with the use of implant-supported fixed dental prosthetics. Initial intraoral scanning was provided by the Medit I500 device (MEDIT corp., Seoul, Korea), while CBCT-scanning was held on Planmeca ProMax® 3D Classic (PLANMECA OY, Helsinki, Finland). Dental occlusion analysis and control over muscle adaptation were held via the Teethan device (Teethan S.p.A., Milan, Italy). OHIP-EDENT questionnaire and Oral Satisfaction Scale were used to assess the improvements of patient-oriented subjective criteria. Results.Treatment protocol provided with the complex diagnostic “TRIDENT” algorithm supported superior time efficiency of treatment (p < 0.05), and statistically significant improvements of several domains within OHIP-EDENT (p < 0.05), OSS values (p < 0.05) and patient adaptation criterion (p < 0.05) at 1, 2, 3, 4, 5, and 6 first weeks of ongoing monitoring. Bone level changes, implant success, and implant survival parameters after 1 year of monitoring have not demonstrated statistically significant deviations as compared to those registered among patients rehabilitated by classical implant placement protocols (p > 0,05). Conclusions.Dental implant treatment protocol with further prosthetic rehabilitation supported by the complex diagnostic “TRIDENT” algorithm demonstrated higher patient-oriented subjective efficiency up to the timepoint of 6 weeks of monitoring after initial prosthetics fixation.
Тип: Text
Тип публикации: Стаття
URI (Унифицированный идентификатор ресурса): https://dspace.uzhnu.edu.ua/jspui/handle/lib/47238
ISSN: 0300-5712
Располагается в коллекциях:Наукові публікації кафедри терапевтичної стоматології

Файлы этого ресурса:
Файл Описание РазмерФормат 
1-s2.0-S0300571222000720-main (1).pdf160.16 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.