Please use this identifier to cite or link to this item: https://dspace.uzhnu.edu.ua/jspui/handle/lib/47239
Title: Can the Density of Mineralized Dental Tissues (Dentin and Enamel) Be Measured and Compared with 3D Cone Beam Computed Tomography in Cases of Ectodermal Dysplasia?
Authors: Yavuz, Y.
Akleyin, E.
Doğan, M.
Goncharuk-Khomyn, M.
Akkus, Z.
Keywords: CBCT, Hounsfield Units, Mineral Density, Ectodermal Dysplasia
Issue Date: 2022
Publisher: Medical Science Monitor: International Medical Journal of Experimental and Clinical Research
Citation: Yavuz, Y., Akleyin, E., Doğan, M. S., Goncharuk-Khomyn, M., & Akkus, Z. (2022). Can the Density of Mineralized Dental Tissues (Dentin and Enamel) Be Measured and Compared with 3D Cone Beam Computed Tomography in Cases of Ectodermal Dysplasia?. Medical Science Monitor: International Medical Journal of Experimental and Clinical Research, 28, e937003-1.
Series/Report no.: 28;
Abstract: Background: Since 3-dimensional cone beam computed tomography (CBCT) started to be used in dentistry, mineral density can now be examined with computer software from the data on the images obtained. Detailed and clear images at different slice intervals can be obtained with CBCT, and mineral density can be measured from the image data on a computer with a Hounsfield unit (HU) scale. In addition to the broad opportunities presented by CBCT, this feature has presented a wider perspective to researchers. Material/Methods: In this study, the CBCT images obtained from patients with the genetic disorder of ectodermal dysplasia were compared with the images of a control group to determine differences in mineralization of the teeth and to show that these could be compared by measuring the mineral density of dentin and enamel tissues using the HU scale on data from CBCT images. This opens new opportunities for cognitive and implementation research. Results: In the study, CBCT images of 14 ectodermal dysplasia and 14 control group cases previously obtained for various reasons were used. Mineral density measurements were made from 4 different regions of the teeth of the ectodermal dysplasia and control groups (incisor edge of the crown, the center buccal, cervicale line, and apex of the teeth), and the groups were compared. Conclusions: The aim of this study was to provide a new overview of the feasibility and suitability of mineralization measurement of dentin and enamel dental tissues with CBCT in ectodermal dysplasia and control groups.
Type: Text
Publication type: Стаття
URI: https://dspace.uzhnu.edu.ua/jspui/handle/lib/47239
ISSN: 1643-3750
Appears in Collections:Наукові публікації кафедри терапевтичної стоматології

Files in This Item:
File Description SizeFormat 
937003.pdf426.94 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.