Please use this identifier to cite or link to this item: https://dspace.uzhnu.edu.ua/jspui/handle/lib/47243
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFera, M.-
dc.contributor.authorGoncharuk-Khomyn, M.-
dc.contributor.authorFera, O.-
dc.contributor.authorBokoch, A.-
dc.contributor.authorKeniuk, A.-
dc.contributor.authorKryvanych, A.-
dc.contributor.authorФера, Олександр Васильовичuk
dc.contributor.authorГончарук-Хомин, Мирослав Юрійовичuk
dc.contributor.authorФера, Марія Олександрівнаuk
dc.contributor.authorБокоч, Анатолій Васильовичuk
dc.contributor.authorКенюк, Андрій Тарасовичuk
dc.contributor.authorКриванич, Володимир Миколайовичuk
dc.date.accessioned2023-01-26T11:59:58Z-
dc.date.available2023-01-26T11:59:58Z-
dc.date.issued2022-
dc.identifier.citationFera, M., Goncharuk-Khomyn, M., Fera, O., Bokoch, A., Keniuk, A., & Kryvanych, A. (2022). Does the Use of Surface Electromyography Could Improve Quality of Life among Patients Rehabilitated by Mandibular Overdentures on Different Attachments?. Pesquisa Brasileira em Odontopediatria e Clínica Integrada, 22.uk
dc.identifier.issn1983-4632-
dc.identifier.urihttps://dspace.uzhnu.edu.ua/jspui/handle/lib/47243-
dc.description.abstractObjective: To analyze and compare changes of quality of life parameter among dental patients rehabilitated by the implant-supported overdentures with different attachment systems. Material and Methods: Fortyeight patients were recruited as a study cohort. The implant placement procedure was based on the results obtained by CBCT scanning and individualized surgical templates manufactured for correct implant placement. Each individual received two k3Pro Implants (Sure Type with 4.0 or 4.5 mm in diameter) at the intraforaminal area due to standard protocol of implantation provided by the manufacturer under local anesthesia. All patients were distributed between two groups based on the fact of using either Locator- or ball-attachments. Rank correlation was measured using Spearman correlation coefficient, while linear correlation was evaluated by Pearson correlation coefficient. Results: No statistically meaningful differences were noted regarding patients’ distribution among groups considering age (p>0.05) and gender (p>0.05). Provided patient-level analysis demonstrated that increase of conventional full denture service time was positively correlated with escalation of OHIP-EDENT scores. The most prominent intercorrespondences were noted specifically between longevity of denture service and elevation of scores within “Functional limitation” (r=0.61; p<0.05), “Physical pain” (r=0.51; p<0.05) and “Physical disability” (r=0.57; p<0.05) subdomains. No statistically argumented regressions were noted between increase tendency of OHIP-EDENT scores and gender (p>0.05) or age (p>0.05) parameters. Conclusion: Significant improvements of quality of life measured with OHIP-EDENT were noted for both types of attachments compared to the pre-treatment situation independently of additionally provided surface electromyographybased alignment.uk
dc.language.isoukuk
dc.publisherPesquisa Brasileira em Odontopediatria e Clínica Integradauk
dc.relation.ispartofseries22;-
dc.subjectDental Implantation; Dental Prosthesis, Implant-Supported; Quality of Life.uk
dc.titleDoes the Use of Surface Electromyography Could Improve Quality of Life among Patients Rehabilitated by Mandibular Overdentures on Different Attachments?uk
dc.typeTextuk
dc.pubTypeСтаттяuk
Appears in Collections:Наукові публікації кафедри терапевтичної стоматології

Files in This Item:
File Description SizeFormat 
PDF+14+Does+the+Use+of+Surface+Electromyography.pdf990.69 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.