Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: https://dspace.uzhnu.edu.ua/jspui/handle/lib/47243
Название: Does the Use of Surface Electromyography Could Improve Quality of Life among Patients Rehabilitated by Mandibular Overdentures on Different Attachments?
Авторы: Fera, M.
Goncharuk-Khomyn, M.
Fera, O.
Bokoch, A.
Keniuk, A.
Kryvanych, A.
Фера, Олександр Васильович
Гончарук-Хомин, Мирослав Юрійович
Фера, Марія Олександрівна
Бокоч, Анатолій Васильович
Кенюк, Андрій Тарасович
Криванич, Володимир Миколайович
Ключевые слова: Dental Implantation; Dental Prosthesis, Implant-Supported; Quality of Life.
Дата публикации: 2022
Издательство: Pesquisa Brasileira em Odontopediatria e Clínica Integrada
Библиографическое описание: Fera, M., Goncharuk-Khomyn, M., Fera, O., Bokoch, A., Keniuk, A., & Kryvanych, A. (2022). Does the Use of Surface Electromyography Could Improve Quality of Life among Patients Rehabilitated by Mandibular Overdentures on Different Attachments?. Pesquisa Brasileira em Odontopediatria e Clínica Integrada, 22.
Серия/номер: 22;
Краткий осмотр (реферат): Objective: To analyze and compare changes of quality of life parameter among dental patients rehabilitated by the implant-supported overdentures with different attachment systems. Material and Methods: Fortyeight patients were recruited as a study cohort. The implant placement procedure was based on the results obtained by CBCT scanning and individualized surgical templates manufactured for correct implant placement. Each individual received two k3Pro Implants (Sure Type with 4.0 or 4.5 mm in diameter) at the intraforaminal area due to standard protocol of implantation provided by the manufacturer under local anesthesia. All patients were distributed between two groups based on the fact of using either Locator- or ball-attachments. Rank correlation was measured using Spearman correlation coefficient, while linear correlation was evaluated by Pearson correlation coefficient. Results: No statistically meaningful differences were noted regarding patients’ distribution among groups considering age (p>0.05) and gender (p>0.05). Provided patient-level analysis demonstrated that increase of conventional full denture service time was positively correlated with escalation of OHIP-EDENT scores. The most prominent intercorrespondences were noted specifically between longevity of denture service and elevation of scores within “Functional limitation” (r=0.61; p<0.05), “Physical pain” (r=0.51; p<0.05) and “Physical disability” (r=0.57; p<0.05) subdomains. No statistically argumented regressions were noted between increase tendency of OHIP-EDENT scores and gender (p>0.05) or age (p>0.05) parameters. Conclusion: Significant improvements of quality of life measured with OHIP-EDENT were noted for both types of attachments compared to the pre-treatment situation independently of additionally provided surface electromyographybased alignment.
Тип: Text
Тип публикации: Стаття
URI (Унифицированный идентификатор ресурса): https://dspace.uzhnu.edu.ua/jspui/handle/lib/47243
ISSN: 1983-4632
Располагается в коллекциях:Наукові публікації кафедри терапевтичної стоматології

Файлы этого ресурса:
Файл Описание РазмерФормат 
PDF+14+Does+the+Use+of+Surface+Electromyography.pdf990.69 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.