Please use this identifier to cite or link to this item: https://dspace.uzhnu.edu.ua/jspui/handle/lib/50808
Title: Experimental study of bone rebuilding in the periimplantation area under immediate loading on dental implants
Authors: Потапчук, Анатолій Мефодійович
Оніпко, Євген Леонідович
Алмаші, Василь Миколайович
Дедух, Нінель
Костенко, Олександр Євгенійович
Keywords: імплантація зубів, Immediate – implantation, immediate loading, splinting, experiment, ISQ (Implant Stability Quotient), BIC (Bone to Implant Contact)
Issue Date: Apr-2021
Publisher: Wiadomości Lekarskie - Aluna Publishing
Citation: Anatoliy M. Potapchuk, Yevhen L. Onipko, Vasyl M. Almashi, Ninel V. Dedukh, Oleksandr Ye. Kostenko. Experimental study of bone rebuilding in the periimplantation area under immediate loading on dental implants. Wiadomości Lekarskie, VOLUME LXXIV, ISSUE 4, APRIL 2021. Wiad Lek. 2021;74(4):992-997. DOI: 10.36740/WLek202104134
Abstract: The aim: Study of the dynamics of morphological rearrangement of bone under conditions of immediate occlusive functional load and the effect of splinting of implants with temporary orthopedic structures with the analysis of the coefficient of stability of implants during immediate implantation in the experiment. Materials and methods: A series of experiments was performed on 6 male Duroc pigs at the age of 6 months and weighing 40-60 kg. In the course of recent advances, the following methods have been used: the clinical protocol of immediate – implantation of time-consuming clothes, the definition of COEFICIENT, morphometry and light microscopy of the slides, statistical analysis. Results: By morphometric examination after 3 months the BIC in the series with splinting was 1.68 times higher compared to 1 month. studies, in a series of experiments without splinting – 1.9 times, after 3 months. the difference between implantation experiments with splinting components and without splinting is 1.6 times. During the functional study of the resonant – frequency analyzer, there is an increase in the ISQ in the second and third months after surgery, but this figure is higher in the study using the splint component. Conclusions: Stagnation of the shingle component in the case of intrinsic intraoperative functional juvenile implantation accelerates the dynamics of osteointegration, so that high indicators of the efficiency of the implant stability can be achieved.
Type: Text
Publication type: Стаття
URI: https://dspace.uzhnu.edu.ua/jspui/handle/lib/50808
ISSN: 0043-5147
Appears in Collections:Наукові публікації кафедри фундаментальних медичних дисциплін

Files in This Item:
File Description SizeFormat 
EXPERIMENTAL_STUDY_OF_BONE_REBUILDING_IN_THE_PERII.pdf358.5 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.