Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: https://dspace.uzhnu.edu.ua/jspui/handle/lib/60117
Название: Automated measuring system for studying the temperature dependence of dielectric spectra of ferroelectrics
Авторы: Ban, Henrietta
Gal, David
Gerasimov, Vitaly
Haysak, Andriy
Molnar, Alexander
Ключевые слова: dielectric spectra, temperature dependence, ferroelectrics
Дата публикации: 22-сен-2021
Издательство: IEEE, Faculty of Electrical and Computer Engineering, Cracow University of Technology, Cracow, Poland
Библиографическое описание: Automated measuring system for studying the temperature dependence of dielectric spectra of ferroelectrics / Henrietta Bán, David Gal, Vitaly Gerasimov, Andriy Haysak, Alexander Molnar // IDAACS 2021 The 11th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications. - September 22-25, 2021. - Cracow, Poland. - p.156-159.
Краткий осмотр (реферат): An automated measuring system developed by authors for studying the temperature dependence of dielectric spectra of ferroelectrics in the frequency range 12Hz-100kHz, the temperature range 80-450K and the amplitude of the measuring signal 5mV-1.275V has been presented. It is based on the GW Instek LCR-819 LCR Meter, the Measurement Computing USB-TEMP-AI temperature meter and an OWON ODP3033 programmable power supply. The temperature measurement resolution is 0.001K and the controlled rate of temperature change is from 0.001K/min to 1K/min. The control software, created in the LabVIEW graphical environment, makes it possible to carry out measurements in an automatic mode, present the results obtained in the form of graphs (Cole-Cole plot and frequency dependency of ε’ and ε”) and save the data as a file for further processing.
Описание: An automated measuring system developed by authors for studying the temperature dependence of dielectric spectra of ferroelectrics in the frequency range 12Hz-100kHz, the temperature range 80-450K and the amplitude of the measuring signal 5mV-1.275V has been presented. It is based on the GW Instek LCR-819 LCR Meter, the Measurement Computing USB-TEMP-AI temperature meter and an OWON ODP3033 programmable power supply. The temperature measurement resolution is 0.001K and the controlled rate of temperature change is from 0.001K/min to 1K/min. The control software, created in the LabVIEW graphical environment, makes it possible to carry out measurements in an automatic mode, present the results obtained in the form of graphs (Cole-Cole plot and frequency dependency of ε’ and ε”) and save the data as a file for further processing.
Тип: Text
Тип публикации: Стаття
URI (Унифицированный идентификатор ресурса): https://dspace.uzhnu.edu.ua/jspui/handle/lib/60117
Располагается в коллекциях:Наукові публікації кафедри фізики напівпровідників

Файлы этого ресурса:
Файл Описание РазмерФормат 
2021_IDAACS_VOL_1_156 (3).pdfarticle1.73 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.