Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал:
https://dspace.uzhnu.edu.ua/jspui/handle/lib/60117
Назва: | Automated measuring system for studying the temperature dependence of dielectric spectra of ferroelectrics |
Автори: | Ban, Henrietta Gal, David Gerasimov, Vitaly Haysak, Andriy Molnar, Alexander |
Ключові слова: | dielectric spectra, temperature dependence, ferroelectrics |
Дата публікації: | 22-вер-2021 |
Видавництво: | IEEE, Faculty of Electrical and Computer Engineering, Cracow University of Technology, Cracow, Poland |
Бібліографічний опис: | Automated measuring system for studying the temperature dependence of dielectric spectra of ferroelectrics / Henrietta Bán, David Gal, Vitaly Gerasimov, Andriy Haysak, Alexander Molnar // IDAACS 2021 The 11th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications. - September 22-25, 2021. - Cracow, Poland. - p.156-159. |
Короткий огляд (реферат): | An automated measuring system developed by authors for studying the temperature dependence of dielectric spectra of ferroelectrics in the frequency range 12Hz-100kHz, the temperature range 80-450K and the amplitude of the measuring signal 5mV-1.275V has been presented. It is based on the GW Instek LCR-819 LCR Meter, the Measurement Computing USB-TEMP-AI temperature meter and an OWON ODP3033 programmable power supply. The temperature measurement resolution is 0.001K and the controlled rate of temperature change is from 0.001K/min to 1K/min. The control software, created in the LabVIEW graphical environment, makes it possible to carry out measurements in an automatic mode, present the results obtained in the form of graphs (Cole-Cole plot and frequency dependency of ε’ and ε”) and save the data as a file for further processing. |
Опис: | An automated measuring system developed by authors for studying the temperature dependence of dielectric spectra of ferroelectrics in the frequency range 12Hz-100kHz, the temperature range 80-450K and the amplitude of the measuring signal 5mV-1.275V has been presented. It is based on the GW Instek LCR-819 LCR Meter, the Measurement Computing USB-TEMP-AI temperature meter and an OWON ODP3033 programmable power supply. The temperature measurement resolution is 0.001K and the controlled rate of temperature change is from 0.001K/min to 1K/min. The control software, created in the LabVIEW graphical environment, makes it possible to carry out measurements in an automatic mode, present the results obtained in the form of graphs (Cole-Cole plot and frequency dependency of ε’ and ε”) and save the data as a file for further processing. |
Тип: | Text |
Тип публікації: | Стаття |
URI (Уніфікований ідентифікатор ресурсу): | https://dspace.uzhnu.edu.ua/jspui/handle/lib/60117 |
Розташовується у зібраннях: | Наукові публікації кафедри фізики напівпровідників |
Файли цього матеріалу:
Файл | Опис | Розмір | Формат | |
---|---|---|---|---|
2021_IDAACS_VOL_1_156 (3).pdf | article | 1.73 MB | Adobe PDF | Переглянути/Відкрити |
Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.